Frequency Range: 1-18 GHz in octave bands
Attenuation range: 0-65 dB
Control Voltage range: 1-10 VDC (or 12-bit digital control)
Average transfer function: 10 +/- 0.5 dB/V
Digital Attenuation steps: 0.25 dB (min)
RF input power: 20 mW operating: 1 W max
Response time: 150 ns - 700 ns
Deviation from linear: +/- 0.5 dB nominal
Flatness over frequency: 1 dB nominal
Variation with temperature: +/- 0.5 dB
Temperature ranges: -55 to +85 C typical
DC Power: +/- 12 VDC typical
For pdf catalog:
Subsystem Products
|