Teledyne Ferretec
Yig Ferretrac Filters
Closed-Loop YIG Filters - Ferretrac® Filters Are Always On Frequency
Systems and instrument designers have frequency application for electronically tunable bandpass and band reject filters. When considering currently available open-loop YIG tuned filters, the designer cannot simply specify the desired systems RF performance. Tuning errors, due to non linearity, hysteresis, temperature drift, driver component aging, etc., require that the RF bandwidth of the filter be widened in a attempt to keep a minimum acceptable bandwidth on frequency under all conditions. This necessitates compromises in the system performance parameters, such as selectivity, image rejection, and passband ripple. Aging of the components also requires the end user to employ frequency and expensive field alignment to maintain these filters on frequency.

For pdf catalog: YIG Filter Products
Application Note: Improving Microwave Measurements
Features:
Closed Loop Locks Filter on Frequency
  • Completely Self Contained... Minimizes User Installation and Maintenance.
  • Reduces Logistics Costs
  • Accurate... No Hysteresis, Non-Linearity, or Temperature Drift
  • Minimized Unwanted Harmonics and Spurious Signals
  • Fast Tuning
  • Full MIL-SPEC Units Available
  • Operates with any oscillator as a preselector in a Receiver Front-End
  • Also Available in Band-Reject Configurations
  • Ideal for automated test applications
    Ferretec's FERRETRAC filters contain a unique reference loop circuit that allows a tunable filter to be locked to an RF signal (a receiver local oscillator, for example). All the normal tuning errors are corrected by the loop gain. The designer can now return to specifying the primary system goals of optimum RF performance.

    The key to FERRETRAC filter operation is an additional YIG sphere located in the same magnetic structure as the filter. Thus, any variations in magnetic field, which would tend to tune the filter to other than the desired frequency, is also sensed by this additional reference sphere. The reference sphere is surrounded by a small air coil which can be biased to establish any desired fixed offset, up to +/-300 MHz, between the reference sphere and the filter. Together with elements of the loop circuits, the reference sphere and air coil form a unique microwave discriminator. The output of this discriminator is a voltage proportional to the error between the quiescent tuned frequency of the YIG filter and the RF reference frequency (+ or - any deliberate offset). This error is fed back to the main electromagnet driver to force the filter onto the reference frequency and keep it there under all static and dynamic conditions of temperature, vibration, driver component aging, etc.

    Figure 1 shows the block diagram of the basic FERRETRAC device. Note that the closed-loop circuits are independent of the filter, allowing complete flexibility for design and optimization of the filter.

    Bandpass Closed-Loop "Tracking" Filter
    MODEL NUMBER
    Tuning Range
    (GHz)
    BW
    (MHz min)
    IL
    (dB max)
    IR
    (dB max)
    ORI
    (dB min)
    2 Stage
    FT1741
    0.5-2.0
    15.0
    4.0
    1.5
    40
    FT2500
    2.0-20.0
    15.0
    4.0
    1.5
    40
    FT1749
    2.0-26.5
    15.0
    5.0
    2.0
    40
    4 Stage
    FT1751
    0.5-2.0
    15.0
    7.0
    1.5
    70
    FT2510
    2.0-20.0
    15.0
    7.0
    1.5
    80
    FT1759
    2.0-26.5
    15.0
    8.0
    2.0
    70
    FT1777
    20.0-40.0
    15.0
    8.0
    2.0
    60
    Also available with Model C1001 Ferretac® Filter Controller.
    Bandpass Closed-Loop "Offset" Filter (160 MHz Offset)
    MODEL NUMBER
    Tuning Range
    (GHz)
    BW
    (MHz min)
    IL
    (dB max)
    IR
    (dB max)
    Rejection
    (dB min)
    F0-160 MHZ
    Rejection
    (dB min)
    F0320 MHZ
    ORI
    (dB min)
    2 Stage
    FT1001
    0.5-2.0
    10
    4.0
    1.5
    35
    40
    40
    FT1002
    2.0-8.0
    20
    3.0
    1.5
    30
    40
    45
    FT1003
    6.0-18.0
    20
    3.0
    1.5
    25
    35
    45
    FT1004
    8.0-18.0
    20
    3.0
    1.5
    25
    35
    45
    FT1005
    2.0-18.0
    15
    4.0
    1.5
    25
    35
    40
    FT1006
    18.0-26.5
    20
    4.0
    2.0
    25
    35
    40
    FT1007
    20.0-40.0
    15
    5.0
    2.0
    25
    35
    35
    4 Stage
    FT10011
    0.5-2.0
    10
    7.0
    1.5
    70
    70
    70
    FT10012
    2.0-8.0
    20
    5.0
    1.5
    60
    70
    80
    FT10013
    6.0-18.0
    20
    4.5
    1.5
    50
    70
    80
    FT10014
    8.0-18.0
    20
    4.5
    1.5
    50
    70
    80
    FT10015
    2.0-18.0
    15
    6.0
    1.5
    50
    70
    80
    FT10016
    18.0-26.5
    20
    6.0
    2.0
    50
    70
    70
    FT10017
    20.0-40.0
    15
    8.0
    2.0
    40
    60
    60
    Offsets in the range -300 MHz to +300 MHz are available either factory set or variable. Negative (-) offset indicates a reference below the filter tuned frequency and Positive (+) offset indicates a reference above the filter tuned frequency.
    Other related products include:
    YIG Bandpass Filters
    YIG Band Reject Filters
    Model C1001 Ferretac® Filter Controller
    Integrated Assy's
    Improving Microwave Measurements with Ferretrac AppNote
     
     
    Teledyne Microwave
    1274 Terra Bella Avenue, Mountain View, California 94043

     Main Number : 650-691-9800  Sales: 650-962-6944